- Model NO.: AAAC 240MM2
- Voltage: High Voltage Cable
- Insulation Material: Bare
- Material Shape: Round Wire
- Model: AAAC 50mm2
- Material of Conductor: Aluminum Alloy
- Standard: IEC,ASTM,BS,DIN,GB/T
- Company Type: Manufacturer
- Transport Package: Wooden Drum; Wooden Steel Drum; All Steel Drum
- Origin: China
- Application: Overhead
- Current: DC Cable
- Sheath Material: None
- Certification: ISO, CCC, CE, RoHS, UL, VDE
- Brand: Huatong
- Color: Silver
- Usage: Transmission Line
- Trademark: HuaTong
- Specification: AAAC 240MM2
AAAC (All Aluminum Alloy Conductor) referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;
Â
Having lower breaking loads than the latter, their use becomes particularly favourable when ice and win loadings are low.Â
We can supply this conductor according to different recognized standards, such as BS EN50182, IEC61089, ASTM B399DIN 48, customer special specification also can be satisfied.Â
Â
2. Â Applications:
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics. Aluminum-alloy gives 6201-T81 gives AAAC higher resistance to corrosion than ACSR.
Â
Â
                        ALUMINIUM ALLOY CONDUCTOR             ASTM B399 | |||||||||
Code Name | Area | Size&Stranding of ACSR with equal diameter | No. and diameter | Overall diameter | Weight | Nominal breaking load | MAX .DC resistance at 20ºC | ||
Nominal | Actual | AWG or MCM | Al/St | ||||||
 | MCM | mm2 |  |  | mm | mm | kg/km | kN | ohm/km |
AKRON | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 | 0.3966 |
ALTON | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68 | 7.84 | 0.3811 |
AMES | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 | 0.3671 |
AZUSA | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 | 0.3524 |
ANAHEIM | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 | 0.3448 |
AMHERST | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 | 0.3375 |
ALLIANCE | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 | 0.3306 |
BUTTE | 312.8 | 158.6 | 266.8 | 26/7 | 19/3.26 | 16.3 | 437 | 48.76 | 0.3196 |
CANTON | 394.5 | 199.9 | 366.4 | 26/7 | 19/3.66 | 18.3 | 551 | 58.91 | 0.3124 |
CAIRO | 465.4 | 235.8 | 397.5 | 26/7 | 19/3.98 | 19.88 | 650 | 69.48 | 0.3071 |
DARIEN | 559.5 | 283.5 | 477 | 26/7 | 19/4.36 | 21.79 | 781 | 83.52 | 0.3014 |
ELGIN | 652.4 | 330.6 | 556.5 | 26/7 | 19/4.71 | 23.54 | 911 | 97.42 | 0.2966 |
FLINT | 740.8 | 375.3 | 636 | 26/7 | 37/3.59 | 25.16 | 1035 | 108.21 | 0.2917 |
GREELY | 927.2 | 469.8 | 795 | 26/7 | 37/4.02 | 28.14 | 1295 | 135.47 | 0.2846 |
 Â
Area | Stranding and wire diameter | Approx. overall diameter | Weight | Nominal Breaking Load | MAX .DC resistance at 20ºC | |
Nominal | Actual | |||||
AWGorMCM | (mm2) | (mm) | (mm) | (kg/km) | (kN) | (ohm/km) |
6 | 13.30 | 7/1.554 | 4.67 | 37 | 4.22 | 2.5199 |
4 | 21.15 | 1/1.961 | 5.89 | 58 | 6.71 | 1.5824 |
2 | 33.63 | 7/2.474 | 7.42 | 93 | 10.68 | 0.9942 |
1/0 | 53.48 | 7/3.119 | 9.36 | 148 | 16.97 | 0.6256 |
2/0 | 67.42 | 7/3.503 | 10.51 | 186 | 20.52 | 0.4959 |
3/0 | 85.03 | 7/3.932 | 11.8 | 234 | 25.86 | 0.3936 |
4/0 | 107.23 | 7/4.417 | 13.26 | 296 | 32.63 | 0.3119 |
250 | 126.66 | 19/2.913 | 14.57 | 349 | 38.93 | 0.2642 |
300 | 152.1 | 19/3.193 | 15.97 | 419 | 46.77 | 0.2199 |
350 | 177.35 | 19/3.447 | 17.24 | 489 | 52.25 | 0.1887 |
400 | 202.71 | 19/3.686 | 18.43 | 559 | 59.74 | 0.1650 |
450 | 228 | 19/3.909 | 19.55 | 629 | 67.19 | 0.1467 |
500 | 253.35 | 19/4.120 | 20.60 | 698 | 74.64 | 0.1321 |
550 | 278.60 | 37/3.096 | 21.67 | 768 | 83.80 | 0.1202 |
600 | 303.80 | 37/3.233 | 22.63 | 838 | 91.38 | 0.1102 |
650 | 329.25 | 37/3.366 | 23.56 | 908 | 97.94 | 0.1016 |
700 | 354.55 | 37/3.493 | 24.45 | 978 | 102.20 | 0.0944 |
750 | 380.20 | 37/3.617 | 25.32 | 1049 | 109.60 | 0.0880 |
800 | 405.15 | 37/3.734 | 26.14 | 1117 | 116.80 | 0.0826 |
900 | 456.16 | 37/3.962 | 27.73 | 1258 | 131.50 | 0.0733 |
1000 | 506.71 | 37/4.176 | 29.23 | 1399 | 146.10 | 0.0660 |
1100 | 557 | 61/3.41 | 30.69 | 1537 | 162.16 | 0.0589 |
1200 | 608 | 61/3.56 | 32.04 | 1677 | 176.75 | 0.0541 |
1300 | 659 | 61/3.71 | 33.39 | 1816 | 191.95 | 0.0498 |
1400 | 709 | 61/3.85 | 34.65 | 1955 | 206.72 | 0.0463 |
1500 | 760 | 61/3.98 | 35.82 | 2095 | 220.90 | 0.0441 |
1600 | 811 | 61/4.12 | 37.08 | 2236 | 235.57 | 0.0405 |
1700 | 861 | 61/4.24 | 38.16 | 2374 | 250.72 | 0.0382 |
1800 | 912 | 61/4.36 | 39.28 | 2514 | 265.11 | 0.03693 |
1900 | 963 | 91/3.67 | 40.37 | 2655 | 277.10 | 0.03411 |
2000 | 1013 | 91/3.76 | 41.4 | 2793 | 292.41 | 0.03243 |
Â
                                     ALUMINIUM ALLOY CONDUCTOR       BSEN50183 | |||||||
Code Name | Calculated Area | No. Of Wires | Diameter | Weight | Rated Strength | MAX .DC resistance at 20ºC | |
Wire | Cond. | ||||||
 | mm2 |  | mm | mm | kg/km | Kn | ohm/km |
Box | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.748 |
Acacia | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
Almond | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
Cedar | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
Deodar | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
Fir | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
Hazel | 59.9 | 7 | 3.3 | 9.9 | 163.4 | 17.66 | 0.5494 |
Pine | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
Holly | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
Willow | 89.7 | 7 | 4.04 | 12.1 | 245 | 26.47 | 0.3665 |
Oak | 118.9 | 7 | 4.65 | 14 | 324.5 | 35.07 | 0.2767 |
Mulberry | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
Ash | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.183 |
Elm | 211 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
Poplar | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
Sycamore | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.4 | 0.1095 |
Upas | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
Yew | 479 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
Totara | 498.1 | 37 | 4.14 | 29 | 1372.1 | 146.93 | 0.0666 |
Rubus | 586.9 | 61 | 3.5 | 31.5 | 1622 | 173.13 | 0.0567 |
Sorbus | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
Araucaria | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
Redwood | 996.2 | 61 | 4.56 | 41 | 2753.2 | 293.88 | 0.0334 |
ALUMINIUM ALLOY CONDUCTORÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â BS 3242 | |||||||
Code Name | Calculated Area | No. Of Wires | Diameter | Weight | Rated Strength | MAX .DC resistance at 20ºC | |
Wire | Cond. | ||||||
 | mm2 |  | mm | mm | kg/km | Kn | ohm/km |
Box | 15 | 7/1.85 | 18.82 | 5.55 | 51 | 537 | 1.7495 |
Acacia | 20 | 7/2.08 | 23.79 | 6.24 | 65 | 680 | 1.384 |
Almond | 25 | 7/2.34 | 30.1 | 7.02 | 82 | 861 | 1.0934 |
Cedar | 30 | 7/2.54 | 35.47 | 7.62 | 97 | 1014 | 0.9281 |
- | 35 | 7/2.77 | 42.18 | 8.31 | 115 | 1205 | 0.7804 |
Fir | 40 | 7/2.95 | 47.87 | 8.85 | 131 | 1367 | 0.688 |
Hazel | 50 | 7/3.30 | 59.87 | 9.9 | 164 | 1711 | 0.5498 |
Pine | 60 | 7/3.61 | 71.65 | 10.83 | 196 | 2048 | 0.4594 |
- | 70 | 7/3.91 | 84.05 | 11.73 | 230 | 2402 | 0.3917 |
Willow | 75 | 7/4.04 | 89.73 | 12.12 | 245 | 2565 | 0.3669 |
- | 80 | 7/4.19 | 96.52 | 12.57 | 264 | 2758 | 0.3441 |
- | 90 | 7/4.44 | 108 | 13.32 | 298 | 3112 | 0.3023 |
Oak | 100 | 7/4.65 | 118.9 | 13.95 | 325 | 3398 | 0.2769 |
- | 100 | 19/2.82 | 118.7 | 14.1 | 326 | 3393 | 0.2787 |
Mulbery | 125 | 19/3.18 | 150.9 | 15.9 | 415 | 4312 | 0.2192 |
Ash | 150 | 19/3.48 | 180.7 | 17.4 | 497 | 5164 | 0.1831 |
Elm | 175 | 19/3.76 | 211 | 18.8 | 580 | 6030 | 0.1568 |
Poplar | 200 | 37/2.87 | 239.4 | 20.09 | 659 | 8841 | 0.1385 |
- | 225 | 37/3.05 | 270.3 | 21.35 | 744 | 7724 | 0.1227 |
Sycamore | 250 | 37/3.22 | 303.2 | 22.54 | 835 | 8664 | 0.1093 |
Upas | 300 | 37/3.53 | 362.1 | 24.71 | 997 | 10350 | 0.09156 |
Walnut | 350 | 37/3.81 | 421.8 | 26.67 | 1162 | 12053 | 0.0786 |
Yew | 400 | 37/4.06 | 479 | 28.42 | 1319 | 13685 | 0.06921 |
Totara | 425 | 37/4.14 | 498.1 | 28.98 | 1372 | 14233 | 0.06656 |
Rubus | 500 | 61/3.50 | 586.9 | 31.5 | 1620 | 16771 | 0.05662 |
Araucaria | 700 | 61/4.14 | 821.1 | 37.26 | 2266 | 23450 | 0.04047 |
(1).What is the difference between ACSR, AAC and AAAC Conductors?
The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel.
Â
The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium.
Â
In an ACSR the galvanised steel core carries the mechanical load and the high purity aluminium carries the current. These utilise the lower thermal expansion coefficient of steel compared to aluminium, which the aluminium based conductors AAC and AAAC are unable to do.
Â
(2). What do ACSR, AAC and AAAC Conductors have in common?
Â
ACSR, AAC and AAAC are all used in overhead line applications, and although for different specific applications, they are all involved in power distribution.
4.FAQ
(1).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please
call us or tell us in your e-mail so that we will regard your inquiry priority.
(2).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight
charge should be paid.
(3).How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7
days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account orprepay us if you do not have an account.
(4).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is
delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months
before the date you would like to get the products at your country.